Datasheet
X24C08
9
D.C. OPERATING CHARACTERISTICS (Over recommneded operating conditions, unless otherwise specified.)
Limits
Symbol Parameter Min. Max. Units Test Conditions
l
CC1
V
CC
Supply Current (Read) 1 SCL = V
CC
x 0.1/V
CC
x 0.9 Levels @ 100
KHz, SDA = Open,
l
CC2
V
CC
Supply Current (Write) 3 mA All Other Inputs = GND or V
CC
– 0.3V
I
SB1
(1)
V
CC
Standby Current 150 µA SCL = SDA = V
CC
– 0.3V, All Other
Inputs = GND or V
CC
, V
CC
= 5.5V
I
SB2
(1)
V
CC
Standby Current 50 µA SCL = SDA = V
CC
– 0.3V, All Other
Inputs = GND or V
CC
, V
CC
= 3V
I
LI
Input Leakage Current 10 µAV
IN
= GND to V
CC
I
LO
Output Leakage Current 10 µAV
OUT
= GND to V
CC
V
lL
(2)
Input Low Voltage –1.0 V
CC
x 0.3 V
V
IH
(2)
Input High Voltage V
CC
x 0.7 V
CC
+ 0.5 V
V
OL
Output Low Voltage 0.4 V I
OL
= 3 mA
3842 PGM T02
*COMMENT
Stresses above those listed under “Absolute Maximum
Ratings” may cause permanent damage to the device.
This is a stress rating only and the functional operation of
the device at these or any other conditions above those
indicated in the operational sections of this specification is
not implied. Exposure to absolute maximum rating con-
ditions for extended periods may affect device reliability.
ABSOLUTE MAXIMUM RATINGS*
Temperature Under Bias..................–65°C to +135°C
Storage Temperature .......................–65°C to +150°C
Voltage on any Pin with
Respect to V
SS
.................................–1.0V to +7V
D.C. Output Current ............................................5 mA
Lead Temperature
(Soldering, 10 Seconds) ...............................300°C
RECOMMENDED OPERATING CONDITIONS
Temperature Min. Max.
Commercial 0°C70°C
Industrial –40°C +85°C
Military –55°C +125°C
Supply Voltage Limits
X24C08 4.5V to 5.5V
X24C08-3.5 3.5V to 5.5V
X24C08-3 3V to 5.5V
X24C08-2.7 2.7V to 5.5V
CAPACITANCE T
A
= 25°C, F = 1.0MHZ, V
CC
= 5V
Symbol Test Max. Units Conditions
C
I/O
(3)
Input/Output Capacitance (SDA) 8 pF V
I/O
= 0V
C
IN
(3)
Input Capacitance (A
0
, A
1
, A
2
, SCL) 6 pF V
IN
= 0V
3842 PGM T04
Notes: (1) Must perform a stop command prior to measurement.
(2) V
IL
min and V
IH
max. are for reference only and are not 100% tested.
(3) This parameter is periodically sampled and not 100% tested.