Datasheet

0 5 10 15 20 25 30
1E-3
1E-2
1E-1
1E+0
1E+1
1E+2
IR(mA)
VR(V)
Tj=100°C
Tj=25°C
1N5820
1N5821
Tj=125°C
Fig. 6-1: Reverse leakage current versus reverse
voltage applied (typical values) (1N5820/1N5821).
0 5 10 15 20 25 30 35 40
1E-3
1E-2
1E-1
1E+0
1E+1
5E+1
IR(mA)
VR(V)
Tj=100°C
Tj=25°C
Tj=125°C
Fig. 6-2: Reverse leakage current versus reverse
voltage applied (typical values) (1N5822).
0.0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 1.1
0.01
0.10
1.00
10.00
50.00
IFM(A)
VFM(V)
Tj=25°C
Tj=100°C
Tj=125°C
Fig. 7-1: Forward voltage drop versus forward
current (typical values) (1N5820/1N5821).
0.0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6
0.01
0.10
1.00
10.00
50.00
IFM(A)
VFM(V)
Tj=25°C
Tj=100°C
Tj=125°C
Fig. 7-2: Forward voltage drop versus forward
current (typical values) (1N5822).
1 10 100 1000
0
20
40
60
80
100
IFSM(A)
Number of cycles
F=50Hz
Tj initial=25°C
Fig. 8: Non repetitive surge peak forward current
versus number of cycles.
1N582x
4/5