Checking flow rate
N Place the unit on the ground.
N Fill the container with water up to 10
liter mark.
Machines without pressure pump
N Set the "standard" metering knob to
"5".
N Start the machine.
N Hold the spray tube horizontally, run
the engine at full throttle, spray the
contents of the container down to
the 5 liter mark and note the time
taken.
The time required to spray 5 liters fluid
should be betweeen 110 and 140
seconds.
Machines with pressure pump
(special accessory)
N Set the "fine" metering knob to 2.3.
N Start the machine.
N Hold the spray tube horizontally, run
the engine at full throttle, spray the
contents of the container down to
the 5 liter mark and note the time
taken.
The time required to spray 5 liters fluid
should be betweeen 90 and 120
seconds.
In case of deviations:
N Check the container, hose system,
metering knob and optional
pressure pump for cantamination
and clean if necessary.
N Check blower air intake and clean if
necessary.
N Check engine setting and correct if
necessary.
If there is no improvement, contact your
dealer for assistance.
Knob position Discharge rate (l/min)
(mean value)
10,69
21,42
31,86
42,25
52,64
Knob position Discharge rate (l/min)
(mean value)
1.0 0,17
1.8 0,43
2.3 0,76
Knob position Discharge rate (l/min)
(mean value)
0.5 0,05
0.65 0,09
0.8 0,14
Knob position Discharge rate (l/min)
1.0 0,66
1.8 1,87
2.3 3,00
Knob position Discharge rate (l/min)
0.5 0,19
0.65 0,33
0.8 0,48