Operation Manual
SR 430, SR 450
English
29
N Press the levers (3) down until the
tabs (2) snap into their seats (6) on
the housing with a loud click.
N Check that the container is firmly
seated.
Blower tube
N Insert a screwdriver into the tab (1)
of the hose clamp (2) on the control
handle.
N Turn the screwdriver clockwise to
loosen the hose clamp (2).
N Pull the hose (3) off the stub.
N Rotate the nozzle (4) until the
lugs (5) are covered.
N Pull the nozzle (4) off the blower
tube (6).
Converting back to misblowing mode
The conversion is carried out in the
reverse sequence.
Fitting the hose
N Push the hose with clamp (2) over
the stub on the control handle.
N Use pliers to squeeze the hose
clamp together (2) until the retaining
strip engages and locks.
N The gasket (1) in the cap must be in
good condition, lubricated with
grease and clean.
N Stand the machine on a level
surface.
N Do not exceed maximum level of 3.7
gal (14 liters) (arrow).
2
2
6
0000-GXX-1171-A0
3
3
6
6
3
1
0002BA036 KN
2
0002BA037 KN
6
5
4
2
0002BA038 KN
Filling the Container
372BA021 KN
1
0002BA039 KN