Operation Manual
SR 200
English
21
Valve Lever
Solution feed is started and stopped with
the valve lever (1).
N Position A (valve lever vertical, up) –
open
N Position B (valve lever horizontal,
down) – closed
Metering Knob
N Rotate the metering knob (1) for
infinitely variable discharge rate
Position 1 = minimum flow rate
Position 6 = maximum flow rate
The numbers on the metering knob must
be lined up with the lug (2) under the
knob.
Discharge Rate
The discharge rate (l/min) depends on
the metering knob setting and the spray
tube angle.
Discharge rate (l/min) without pressure
pump
Discharge rate (l/min) without pressure
pump, with ULV nozzle
Discharge rate (l/min) with pressure
pump (special accessory)
Discharge rate (l/min) with pressure
pump (special accessory) and ULV
nozzle
Checking Flow Rate
N Place the unit on the ground.
N Fill the container with water up to
10 liter mark.
Metering Unit
1
0002BA061 KN
A
B
1
Spray tube angle
Knob setting - 30° 0° + 30°
1 0.240.170.11
2
1
2431BA022 KN
0811BA019 KN
2 0.82 0.66 0.46
3 1.42 1.13 0.84
4 2.2 1.66 1.1
5 2.69 2.13 1.46
6 2.91 2.25 1.52
Spray tube angle
Knob setting - 30° 0° + 30°
0.5 0.05 0.04 0.03
0.65 0.08 0.07 0.05
0.8 0.12 0.09 0.08
Spray tube angle
Knob setting - 30° 0° + 30°
1.0 0.64
1.6 1.7
2.0 2.59
Spray tube angle
Knob setting - 30° 0° + 30°
0.5 0.15
0.65 0.2
0.8 0.37