Removing the Suction Tube
N Switch off the motor.
N Operate the lever (1), rotate the
union nut (2) in direction of arrow as
far as the stop and remove together
with the suction tube.
N Position the intake screen (3) on the
intake opening.
N Line up the arrows (4).
N Rotate the intake screen nut (3) in
direction of arrow until the lever (5)
engages audibly on the fan housing.
The voltage and frequency of the
machine (see rating plate) must match
the voltage and frequency of the power
connection.
The minimum fuse protection of the
power connection must comply with the
specifications – see "Specifications".
The machine must be connected to the
power supply via an earth-leakage
circuit breaker to disconnect the power
supply if the differential current to earth
exceeds 30 mA.
The power connection must correspond
to IEC 60364 and relevant national
regulations.
Extension cord
The design of the extension cord must at
least fulfill the same features as the
connecting cord on the machine.
Observe the design marking (type
designation) on the connecting cord.
The cores in the cord must have the
following minimum cross-section
depending on the mains voltage and
cord length.
Strain relief (cord retainer)
The strain relief protects the appliance
cord against damage.
N Insert the plug (1) into the extension
cord coupling (2).
N Make a loop in the extension cord.
N Pass the loop (3) through the
opening (4).
N Slip the loop over the hook (5) and
pull it tight.
Connecting to Wall Outlet
Make sure your machine is switched off
before you connect it to the power
supply – see "Switching Off".
N Connect the extension cord plug to
a properly installed wall outlet.
290BA011 KN
5
4
290BA017 KN
Connecting to Power Supply
Cord length Minimum cross-
section
220 V – 240 V:
Up to 20 m 1.5 mm
2
20 m to 50 m 2.5 mm
2
100 V – 127 V:
Up to 10 m AWG 14 / 2.0 mm
2
10 m to 30 m AWG 12 / 3.5 mm
2