Troubleshooting
Before starting troubleshooting, operate the unit until it is no longer under pressure – if pressure is not released, solution may
escape unexpectedly when working on the hose and pump system.
After servicing, carry out test run with clean water.
Condition Cause Remedy
No spray from nozzle Hose and wand system blocked Rinse and clean all parts of the hose and
wand system with clean water (spray gun,
filter in gun, spray wand, hose)
Water accumulates in piston. Liquid has been stored in the tank for too long Remove the piston from the pump and
lubricate the pump with oil
1)
. Rinse the
tank with clean water after every use
Liquid leaks from top of pump when
pumping.
Worn O-ring on piston Fit new O-ring on piston
1)
Lever falls down under own weight Ball (intake side) is sticking Remove hose from bottom of pump hous-
ing and take out the ball. Clean the ball
and make sure it moves freely
Lever moves upwards of its own
accord
Ball (delivery side) is sticking Open screw plug in the pump housing and
take out the ball. Clean the ball and make
sure it moves freely
Pumping action produces no pressure No suction Fit new O-ring on piston
1)
. Check that
balls in the pump housing’s valve seats
are properly seated and not sticking
1)
STIHL recommends an authorized STIHL servicing dealer.