User Instructions

Table Of Contents
0478 131 9954 C - EN
180
Message:
2110 – GPS protect.
New location
New installation req.
Possible cause:
The robotic mower was operated on a
different mowing area. The wire signal
of a second docking station is already
stored.
Remedy:
Perform new installation (Ö 11.13)
Message:
2400 – iMOW® successfully reset to
factory default
Possible cause:
Robotic mower has been reset to
factory default
Remedy:
Confirm message with OK
Message:
4000 – Voltage fault
Battery overvoltage or undervoltage
Possible cause:
Battery overvoltage or undervoltage
Remedy:
No action required, firmware will be
automatically updated if necessary
Contact your STIHL specialist dealer if
the problem persists
Message:
4001 – Temperature fault
Outside temperature range
Possible cause:
Temperature in the battery or inside the
machine too low or too high
Remedy:
Allow robotic mower to warm up or cool
down – observe permissible
temperature range of battery (Ö 6.4)
Message:
4002 – Rollover
see message 1000
Message:
4003 – Hood lifted
Check hood
Then press OK
Possible cause:
Hood has been lifted
Remedy:
Check the hood and confirm the
message with OK
Message:
4004 – Drive braking time exceeded
Press OK to release
Possible cause:
Error in the programme sequence
Wire routing incorrect
Obstacles in the area of the perimeter
wire
Remedy:
Confirm message with OK
Check wire routing, especially in the
area of the corners, using the
iMOW® Ruler (Ö 12.5)
Remove obstacles
Message:
4005 – Blade braking time exceeded
Please OK to release
Possible cause:
Error in the programme sequence
Signal collapse (e.g. due to a power
failure) during automatic mowing
Remedy:
Confirm message with OK
Check power supply to the docking
station – the red LED must be
illuminated permanently during
operation; then press the OK
button (Ö 13.1)
Message:
4006 – Charging interrupted
Press OK to release
Possible cause:
Error in the programme sequence
Power failure during charging
Robotic mower rolled out of the docking
station
Remedy:
Confirm message with OK
Check power supply to the docking
station – the red LED flashes slowly
when the robotic mower is
docked (Ö 13.1)
Check that the docking station is in the
correct position (Ö 9.1)
Message:
4008 – Control panel recogn. faulty
Press OK to release
Possible cause:
Control panel not correctly inserted
Remedy:
Insert the control panel
Confirm message with OK