User Instructions

Table Of Contents
0478 131 9957 B - EN
172
Message:
1030 – Hood fault
Check hood
Then press OK
Possible cause:
No hood detected
Remedy:
Check hood (movement, firm seating)
and confirm the message with OK
Message:
1105 – Flap open
Operation aborted
Possible cause:
Flap open during automatic operation
Flap open during automatic edge
following
Remedy:
Close the flap (Ö 15.2)
Message:
1120 – Hood blocked
Check hood
Then press OK
Possible cause:
Permanent collision detected
Remedy:
Free the robotic mower, remove the
obstacle or change routing of perimeter
wire if necessary – then confirm the
message with OK
Check movement of the hood and
confirm the message with OK
Message:
1125 – Remove obstacle
Check wire routing
Possible cause:
Perimeter wire routed inaccurately
Remedy:
Check routing of the perimeter wire,
check clearances using the
iMOW® Ruler (Ö 12.5)
Message:
1130 – Stuck
Free iMOW®
then press OK
Possible cause:
Robotic mower has become stuck
Drive wheels are spinning
Remedy:
Free the robotic mower, level out the
mowing area or change the routing of
the perimeter wire if necessary – then
confirm message with OK
Clean the drive wheels, if necessary
prevent operation during rain – then
confirm message with OK (Ö 11.10)
Message:
1135 – Outside
Place the iMOW® on the mowing area
Possible cause:
The robotic mower is located outside
the mowing area
Remedy:
Return robotic mower to the mowing
area
Message:
1140 – Too steep
Check wire routing
Possible cause:
RMI 422:
Tilt sensor has detected a slope
inclination exceeding 35%
–RMI422P:
Tilt sensor has detected a slope
inclination exceeding 40%
Remedy:
RMI 422:
Change routing of perimeter wire, block
off lawns with slope inclinations
exceeding 35%
–RMI422P:
Change routing of perimeter wire, block
off lawns with slope inclinations
exceeding 40%
Message:
1170 – No signal
Switch on docking station
Possible cause:
Docking station is switched off
No reception of wire signal during
operation
The robotic mower is located outside
the mowing area
Docking station or electronic
components were replaced
Remedy:
Switch on docking station and give
mowing command
Check power supply to the docking
station
Check LED on the docking station – the
red LED must be permanently
illuminated during operation (Ö 13.1)
Return robotic mower to the mowing
area