User Instructions

Table Of Contents
161
DEFRNLIT EN
0478 131 9944 C - EN
Message:
0001 – Data updated
Press OK to release
Possible cause:
The machine software has been
updated
Voltage loss
Software or hardware error
Remedy:
After the OK button is pressed, the
robotic mower operates with the default
settings – check and correct the
settings (date, time, mowing plan)
Message:
0100 – Battery discharged
Charge battery
Possible cause:
Battery voltage too low
Remedy:
Place the robotic mower in the docking
station to recharge the battery (Ö 15.7)
Message:
0180 – Temperature low
Temperature range not reached
Possible cause:
Temperature inside the robotic mower
too low
Remedy:
Warm up the robotic mower
Message:
0181 – Temperature high
Temperature range exceeded
Possible cause:
Temperature inside the robotic mower
too high
Remedy:
Allow the robotic mower to cool down
Message:
0183 – Temperature high
see message 0181
Message:
0185 – Temperature high
see message 0181
Message:
0186 – Temperature low
see message 0180
Message:
0187 – Temperature high
see message 0181
Message:
0302 – Drive motor fault
Temperature range exceeded
Possible cause:
Temperature in left drive motor too high
Remedy:
Allow the robotic mower to cool down
Message:
0305 – Drive motor fault
Left wheel is stuck
Possible cause:
Overload at left drive wheel
Remedy:
Clean the robotic mower (Ö 16.2)
Level out any uneven areas (holes,
depressions) in the mowing area
Message:
0402 – Drive motor fault
Temperature range exceeded
Possible cause:
Temperature in right drive motor too
high
Remedy:
Allow the robotic mower to cool down
Message:
0405 – Drive motor fault
Right wheel is stuck
Possible cause:
Overload at right drive wheel
Remedy:
Clean the robotic mower (Ö 16.2)
Level out any uneven areas (holes,
depressions) in the mowing area
Message:
0502 – Mowing motor fault
Temperature range exceeded
Possible cause:
Temperature in mowing motor too high
Remedy:
Allow the robotic mower to cool down