User Instructions

Table Of Contents
107
DEFRNLIT EN
0478 131 9944 C - EN
The docking station must not be inclined
by more than 8 cm rearwards or 2 cm
forwards. Never bend the floor plate. Any
unevenness must be removed under the
floor plate so that it fully contacts the
ground.
Installation options:
The docking station can be installed
internally and externally.
Internal docking station:
The docking station (1) is installed within
the mowing area (A), right at the edge.
There must be a free, level area (2) with a
radius of at least 1 m in front of the docking
station (1). Remove any bumps or
depressions.
Route the perimeter wire (2) in front of and
behind the docking station (1) for 0.6 m in
a straight line and at right angles to the
floor plate. Then follow the edge of the
mowing area with the perimeter wire.
External docking station:
The docking station (1) is installed outside
the mowing area (A).
In conjunction with an external
docking station, guide loops must
be installed for offset drive home.
(Ö 12.12)