Instruction Manual

RE 362, RE 362 PLUS, RE 462, RE 462 PLUS
English
41
High-pressure hose and
spray attachment in good
condition (clean, moving
easily) and correctly
assembled
For good control of the
machine, the handles
should be clean and dry
with no oil or dirt on them
Check oil level
Never attempt to modify
the controls or safety
devices in any way
Set up the machine so that
it cannot slip or tip over.
Only operate the machine
on a stable and level
ground
Electrical connection
WARNING
Minimize the risk of electrical
shock:
Voltage and frequency of
the machine (see rating
plate) must match the
voltage and frequency of
the mains supply
Examine the connecting
cord, power plug and
extension cord for
damage. Do not use the
machine with a damaged
connecting cord, extension
cord or damaged power
plug
Only connect the machine
to a correctly installed
power socket
The insulation on the
connecting cord and any
extension cord, the plug
and the coupling must be
fully intact
Never touch the power
plug, connecting cord and
extension cord, and
electrical plug connections
with wet hands
WARNING
Route the connecting cord
and extension cord properly:
Observe the minimum
cross-section of the
individual cords – see
"Connecting the machine
to the power supply"
Route and mark the power
cord so that it cannot
become damaged and no
one is endangered risk of
stumbling!
Use of unsuitable
extension cords can be
dangerous. Use only
extension cords that are
approved for outdoor use
and are correspondingly
marked and have a
sufficient cross-section
The connector and
coupling of the extension
cord must be waterproof
and must not lie in water
It is advisable to keep the
plug connection at least
60 mm above the
ground/floor, e. g. by using
a cable reel
Don't let the cord rub
against edges or pointed
or sharp objects