Fault Cause Remedy
The circuit-breaker (fuse) or the earth-
leakage circuit breaker has tripped.
The circuit is electrically overloaded or
defective.
Find and resolve the cause for the
trip. Engage circuit-breaker (fuse) or
the earth-leakage circuit breaker.
Switch off other electrical consum‐
ers on the same circuit.
The fuse rating of the socket is too
low.
Plug the connecting cord into a
socket with the correct fuse rating,
19.1.
The electric motor is too warm. Allow the pressure washer to cool
for 5 minutes.
Clean the nozzle.
The high-pressure
pump switches on
and off repeatedly,
without the trigger of
the spray gun being
pressed.
The high-pressure pump, the high-
pressure hose or the spray attachment
are leaking.
Ask a STIHL servicing dealer to
check the pressure washer.
The working pressure
fluctuates or drops.
There is a water shortage. Open water tap completely.
Ensure that a sufficient quantity of
water is available.
The nozzle is blocked. Clean the nozzle.
The water intake screen or water filter
are blocked.
Clean water intake screen and water
filter.
The high-pressure pump, the high-
pressure hose or the spray attachment
are leaking or are defective.
Ask a STIHL servicing dealer to
check the pressure washer.
The water jet has
changed shape.
The nozzle is blocked. Clean the nozzle.
The nozzle is worn. Replace nozzle.
Additional detergent
is not drawn in.
The detergent container is empty. Fill the detergent container with
detergent.
Fan jet nozzle is not turned in direction
- up to the stop.
Turn fan jet nozzle in direction - up
to the stop.
Venturi nozzle is worn Have the tool repaired by a STIHL
servicing dealer.
Connections on pres‐
sure washer, high-
pressure hose, spray
gun or spray lance
are difficult to con‐
nect to each other.
The connection seals are not lubrica‐
ted.
Lubricate the gaskets 18.2
18.2 Greasing the gaskets
1
1
1
0000-GXX-9852-A0
Grease gaskets (1) with grease for fittings.
19 Specifications
19.1 Pressure washer STIHL RE
150 PLUS
Version 230 V / 50 Hz
Fuse (characteristic "C" or "K"): 13 A
Power consumption: (EU) 2019/1781 §2(2) (j):
2.9 kW
Maximum permitted network impedance: 0.32
Ohm
protection class: I
Degree of of electrical protection: IPX5
Working pressure (p): 14 MPa (140 bar)
English 19 Specifications
22 0458-663-0121-B