Instruction Manual
Table Of Contents
- 1 Introduction
- 2 Guide to Using this Manual
- 3 Overview
- 4 Safety Precautions
- 4.1 Warning symbols
- 4.2 Intended use
- 4.3 Requirements concerning the user
- 4.4 Clothing and equipment
- 4.5 Work area and surroundings
- 4.6 Safe condition
- 4.7 Operation
- 4.8 Detergents
- 4.9 Connecting the water supply
- 4.10 Connecting to the power supply
- 4.11 Transport
- 4.12 Storage
- 4.13 Cleaning, servicing and repairs
- 5 Safety instructions - Accessories
- 6 Preparing the pressure washer for operation
- 7 Assembling the pressure washer
- 8 Connecting to a water source
- 9 Connecting the pressure washer to the power supply
- 10 Switching the pressure washer on and off
- 11 Operating the pressure washer
- 12 After Finishing Work
- 13 Transporting
- 14 Storing
- 15 Cleaning
- 16 Maintenance
- 17 Repairing
- 18 Troubleshooting
- 19 Specifications
- 20 Spare Parts and Accessories
- 21 Disposal
- 22 EC Declaration of Conformity
0458-616-0121-A
30
English
19 Specifications
18.2 Lubricating the seals
► Grease the seals (1) with grease for fittings.
19.1 Pressure washer STIHL RE 100
– Fuse (characteristic "C" or "K"): 10A
– Power consumption: 1.7kW
– Electrical protection class: I
– Degree of electrical protection: IPX5 (protection from
water jets in any direction)
– Working pressure (p): 11MPa (110bar)
– Max. permissible pressure (pmax.): 12MPa (120bar)
– Max. water supply pressure (pinmax.): 1MPa (10bar)
– Max. water throughput (Qmin): 7.3l/min (440l/h)
– Max. suction lift: 0.5m
– Max. water temperature in pressure mode (tinmax):
40°C
– Max. water temperature in suction mode: 20°C
– Dimensions
– Length: 301mm
– Width: 317mm
– Height: 857mm
– Length of high-pressure hose: 6m
– Weight (m) with accessory attached: 16.6kg
19.2 Extension Cords
If an extension cord is used, the cross sectional area of its
conductors must meet the following minimum requirements
– depending on the line voltage and length of the extension
cord:
220V to 240V
– Cord length up to 20 m: AWG15 / 1.5mm²
– Cord length 20 m up to 50m: AWG13 / 2.5mm²
100V to 127V
– Cord length up to 10m: AWG14 / 2.0mm²
– Cord length 10m up to 30m: AWG12 / 3.5mm²
19.3 Sound and Vibration Levels
– Sound pressure level L
pA
measured according to
EN60335-2-79: 67dB(A). The Kvalue for the sound
pressure level is 2dB(A).
– Sound power level L
wA
measured according to
EN60335-2-79: 81dB(A). The Kvalue for the sound
power level is 2dB(A).
– Vibration level a
h
measured according to EN60335-2-79,
spray gun: ≤2.5m/s². The Kvalue for the vibration level
is 2 m/s².
For information on compliance with the Employers’ Directive
on Vibration 2002/44/EC, see www.stihl.com/vib .
19.4 REACH
REACH is an EC regulation and stands for the Registration,
Evaluation, Authorisation and Restriction of Chemical
substances.