Operation Manual
51MS 360
english
Furthermore, the angles must be the 
same on all cutters. If angles are 
uneven: Chain will run roughly, not in a 
straight line, wear quickly and finally 
break.
As these requirements can be met only 
after sufficient and constant practice:
:
::
: Use a file holder*
A file holder must be used for manual 
resharpening of Super chain. The 
correct filing angle is marked on the file 
holder.
* see “Guide to Using this Manual”
For checking angles
STlHL filing gauge* (see table). 
A universal tool for checking the filing 
and side plate angles, depth gauge 
setting and cutter length. Also cleans the 
guide bar groove and oil inlet hole.
* see “Guide to Using this Manual”
File correctly
: If you use a file holder, the FG 1 or 
FG 3:
Leave the chain on the bar.
: Clamp the bar in a vise if necessary.
: Lock the chain – push hand guard 
forward.
: To rotate the chain – pull hand guard 
against handle.
: Sharpen chain frequently, take 
away as little metal as possible – 
two or three strokes of the file are 
usually enough.
: Always file from the inside to the 
outside of the cutter.
: The file only sharpens on the 
forward stroke – 
lift the file off the cutter on the 
backstroke.
689BA025 KN
90°
60°
85° 70°
80°
0°
35°
10°
30°
689BA022 KN
689BA018 KN
90°