Operation Manual

95MS 241 C
Versions with heating
: Remove screw (1) on front
handle
All versions
: Remove screws (1)
: Push tank housing (2) down
slightly and hold it there
: Push front handle out of the
mount (arrow) on the peg (1)
– Do not remove screws on front
handle
2410RA303 TG
1
2310RA236 TG
1
2
1
2410RA304 TG
1
: Remove cover (1)
: Push the antivibration
element (1) slightly upward and
lift it out of the guide (arrow)
: Remove antiivibration
element (1) between crankcase
and tank housing
Inspect spring and plug, replace if
necessary
2310RA237 TG
1
2310RA238 TG
1
Installation
Push tank housing down slightly
and hold it there
: Orient antivibration element so
that the tab (1) faces the
crankcase and push it bearing
plug (2) first between crankcase
and tank housing
: Push bearing plug (2) through
the opening
: Push the bearing plug (3) into the
mount (arrow)
: Position cover (1) so that it
engages the peg (arrow)
2310RA239 TG
2
1
3
2310RA240 TG
1