Operation Manual

92 MS 241 C
: Press the frame (1) against the
rewind spring and turn it slightly
clockwise until the rewind spring
is completely seated
The rewind spring may pop out.
Carefully remove the frame and
keep it
– The frame is reused as an
installation tool for installing
rewind springs that have popped
out
Make certain that the
rewind spring (1) is inserted
completely and the outer anchor
loop is seated in the anchor loop
mount (arrow), if necessary, press
the rewind spring completely into
the mount in the fan housing.
Secure the rewind spring so that
it cannot pop out
Install the rope rotor, b 9.5
Reassemble remaining parts in
reverse order
2310RA227 TG
1
2310RA228 TG
1
Reinstalling a rewind spring that
has popped out
If the rewind spring pops out during
installation, fit it in the fan housing
as follows:
Arrange the rewind spring (1) as
shown in the illustration
: Insert outer anchor loop in the
recess (arrow) of the fan housing
: Fit the rewind spring (1) in the
spring housing in a circular
fashion, working in clockwise
direction while holding the
inserted turns of the spring in
place
The further course of action is the
same as for "Installing a new rewind
spring".
2310RA230 TG
1
2310RA231 TG
1
Versions with ErgoStart
Install new rewind spring
: Check washer (1) and replace if
necessary
Lubricate replacement spring
with frame with a few drops of
STIHL special lubricant before
installing it, b 16
Position replacement spring with
frame in the fan housing so that the
outer anchor loop (1) is positioned
over the mount for the loop (2) and
aligns with the mount (arrow)
The further course of action is the
same as for "Installing a new rewind
spring" in versions without
ErgoStart.
2310RA223 TG
1
2310RA225 TG
1
2