Operation Manual

87MS 241 C
9.3 Pawls
Remove fan housing, b 9.2
Relieve the tension of the rewind
spring, b 9.5
: Carefully ease the spring (1) off
the starter post
Remove pawl
Installation
Press new pawl into hole (arrow)
and grease the peg (1), b 16
2310RA204 TG
1
2310RA205 TG
1
: Position the spring (1) so that the
loop of the spring encloses the
peg of the pawl and the curved
part of the spring (arrow) is
located in the groove in the
starter post
: Then slide the straight part of the
spring over the starter post until it
engages in the groove
The guide loop of the spring must
run along the pawl (arrow).
Checking correct functioning
Pull starter rope, the rope rotor
turns, and the peg at the pawl
moves in the direction of the
anchor loop – the pawl moves
outward
Reassemble remaining parts in
reverse order
2310RA206 TG
1
2310RA207 TG
Versions with ErgoStart
Remove ErgoStart, b 9.4
Two pawls are installed in the
version with ErgoStart. Removal is
the same as with the standard
version.
Grease the mounts of the new
pawls, b 16
Insert the new pawls and oil the
pegs of the pawls with resin-free
lubricating oil, b 16
Installation
Washer (1) must be fitted.
: Position spring (2) so that its
anchor loops engage the pegs of
the pawls and the curved part of
the spring (arrow) is located in
the groove of the rope rotor post
: Then slide the straight part (3) of
the spring over the starter post
until it engages in the groove
Reassemble remaining parts in
reverse order
2310RA208 TG
1
2
3