Operation Manual
78 MS 241 C
: Position the wiring harness (1) so
that the protective tube (2) rests
against the beginning of the
guide
: Press the red and black leads
completely into the
guides (arrows)
Versions with heating
: Check the lead (1) of the
thermostatic switch, if necessary,
press it completely into the
guides (arrows) on the base of
the carburetor and route it behind
the pin (5)
Plug connectors (2) and (3) and the
generator lead (4) must be seated
completely in the guides.
2410RA251 TG
21
2410RA252 TG
1
2 3
4
5
Versions with manual fuel pump
: Check seat of the fuel return
line (1), if necessary. press it
completely into the
guides (arrows)
All versions
Washer (1) must be fitted.
Do not remove the fuel hose from
the carburetor support.
: Carefully push the carburetor (1)
with the fuel hose (2) over the
studs (arrows) – do not
overextend the fuel hose
2410RA253 TG
1
2410RA078 TG
1
2410RA254 TG
2
1
: Orient plug (1) and jack (2) that
the tab (3) lines up with the
opening (arrow) – do not twist the
leads
: Plug connector (1) into jack (2)
until the tab (3) clicks into place
: Press the plug connection (1)
into the mount (2) of the
carburetor support so that the
tab (arrow) engages and snaps
into place in the recess of the
plug connection
– Plug connection (1) must be
seated firmly in the mount (2)
– Push on the carburetor as far as
it will go – pay attention to cable
routing and make sure not to
pinch any leads
2410RA188 TG
1 2
3
2410RA256 TG
1
2