Operation Manual
71MS 241 C
Screw (1) must be tight.
Leads (arrows) must be seated
completely and firmly in the blade
receptacles and the cable lug.
Plug connection (1) must be
pressed together completely –
locking lug (3) must engage the
recess.
: If necessary. remove the plug
connection (1) from the
mount (arrow), remove the
plug (2) and check the contacts,
b 8.2.3
2410RA217 TG
1
2410RA218 TG
12
3
Versions with heating
: Remove blade receptacle (1) and
contact sleeve (2)
: Push out the holder (3) with
ground wire (4) at the air guide
shroud (5) and lay it aside
Versions with manual fuel pump
: Push out the holder (1) with the
fuel pump at the air guide
shroud (2), remove fuel hose (3)
at the carburetor (arrow) and lay
it on top of the air guide shroud
2
2410RA219 TG
1
3
4
5
3
2410RA220 TG
1
2
All versions
Plug (1) must be seated completely
and firmly in the recess of the
solenoid.
: If necessary, remove plug (1) and
check contacts
: Set Master Control lever (1) to
position }; the cam on the
lever (2) must actuate the
microswitch (arrow) – clicking
sound
– If the microswitch is not actuated
by the lever at the carburetor,
replace lever if necessary,
b 13.6.6
– If the microswitch does not
function although it was actuated,
then the switchgear must be
replaced, b 8.4
2410RA221 TG
1
2410RA222 TG
1
2