Operation Manual

65MS 241 C
: Press contact sleeve (1) of the
short-circuit wire out of the
contact spring (2)
Examine contact spring, replace
if necessary
Installation
: Push the contact sleeve (1) of the
short-circuit wire into the
eye (arrow) of the contact
spring (2) as far as it will go
2410RA210 TG
2
1
2410RA211 TG
1
2
: Position contact spring (1)
against the guide (arrows)
: Lift contact spring (1) slightly at
the connection of the short-circuit
wire and guide it over the tab (2)
– do not overextend the contact
spring
Before pushing the contact
spring (1) all the way in, lift it slightly
and guide it over the switch shaft –
2 mm maximum.
2410RA212 TG
2
1
2310RA153 TG
1
: Push the contact spring (1) into
the guide (arrows) as far it will go,
until the tab surrounds the
contact spring
Install filter base, b 13.3
: Checking correct functioning
– Blade receptacle of the short-
circuit wire must touch the
contact spring (arrow) in position
"
0"
Reassemble remaining parts in
reverse order
2310RA154 TG
1
2310RA155 TG