Operation Manual
62 MS 241 C
: Orient plug (1) and jack (2) that
the tab (3) lines up with the
mount (arrow) – do not twist the
leads
: Plug connector (1) into jack (2)
until the tab (3) clicks into place in
the mount (arrow)
: Press the plug connection (1)
into the mount (2) of the
carburetor support so that the
tab (arrow) engages in the recess
of the plug connection
– Push on the carburetor and
observe cable routing as well as
installation position of the
M-Tronic and, if present, the
heating system, b 8.4
2410RA188 TG
1 2
3
2410RA197 TG
1
2
: Slide the blade receptacle (1) of
the blue ground wire, with the
crimped side facing the cam (2),
into the guide (arrow) as far as it
will go
: Hook ground wire (1) into the
guides (arrows)
– Push switch shaft onto filter base,
b 11.1
– Install contact spring, b 7.7.4
– Install filter base, b 13.3
2410RA199 TG
2
1
2410RA200 TG
1
: Check the routing of the blue
ground wire (1) and black short-
circuit wire (2), if necessary,
press them completely into the
guide (arrow) using wiring tool
5910 890 4000 – wires must rest
snug against the air guide shroud
: Using wiring tool 5910 890 4000,
press the blue ground wire (1)
and black short-circuit wire (2)
into the guides so that the
markings (arrows) are located at
the guide ribs
– Conduct a function test of the
switch shaft, b 11.1
2
2410RA201 TG
1
2
2410RA202 TG
1