Operation Manual

62 MS 241 C
: Orient plug (1) and jack (2) that
the tab (3) lines up with the
mount (arrow) – do not twist the
leads
: Plug connector (1) into jack (2)
until the tab (3) clicks into place in
the mount (arrow)
: Press the plug connection (1)
into the mount (2) of the
carburetor support so that the
tab (arrow) engages in the recess
of the plug connection
Push on the carburetor and
observe cable routing as well as
installation position of the
M-Tronic and, if present, the
heating system, b 8.4
2410RA188 TG
1 2
3
2410RA197 TG
1
2
: Slide the blade receptacle (1) of
the blue ground wire, with the
crimped side facing the cam (2),
into the guide (arrow) as far as it
will go
: Hook ground wire (1) into the
guides (arrows)
Push switch shaft onto filter base,
b 11.1
Install contact spring, b 7.7.4
Install filter base, b 13.3
2410RA199 TG
2
1
2410RA200 TG
1
: Check the routing of the blue
ground wire (1) and black short-
circuit wire (2), if necessary,
press them completely into the
guide (arrow) using wiring tool
5910 890 4000 – wires must rest
snug against the air guide shroud
: Using wiring tool 5910 890 4000,
press the blue ground wire (1)
and black short-circuit wire (2)
into the guides so that the
markings (arrows) are located at
the guide ribs
Conduct a function test of the
switch shaft, b 11.1
2
2410RA201 TG
1
2
2410RA202 TG
1