Operation Manual

59MS 241 C
: Remove diagnostic jack (1) with
connector housing (2) from the
guides (arrows)
: Pry out and remove the cable
holder (1) at the pin (arrow)
: Remove wiring harness (1) from
the guides (arrows) of the air
guide shroud
2410RA174 TG
1
2
2410RA175 TG
1
2410RA176 TG
1
: Pull out grommet (1) with wiring
harness
: Remove ground wire (1) from the
guides (arrows)
: Remove ground wire (1) from the
guide (arrow)
: Remove the switch shaft (2)
2410RA177 TG
1
2410RA178 TG
1
2410RA179 TG
1
2
: Pull the retaining tab (1) in the
direction of the leads and open
the cover (2)
: Pull blade receptacles (1) out of
the insulating sleeve (2)
Check blade receptacles and
insulating sleeves, clean or
replace insulating sleeves if
necessary
With a new wiring harness, the
grommets and the plugs as well as
the insulating sleeve are pre-
assembled.
2410RA180 TG
1
2
2410RA181 TG
1
2
1