Operation Manual
167MS 241 C
: Run the thin wire (1) with a
loop (arrow) around the fin and
press it into the guide as far as it
will go
: Position insulating tube (1) with
plug connection at the edge of
the tank housing and push it into
the guide (arrow) as far as it will
go
– Install cover over the plug
connections, lift and fasten tank
housing, b 10.4.1
– Install air guide shroud, b 13.4.2
– Reassemble remaining parts in
reverse order
2410RA424 TG
1
2410RA425 TG
1
14.9 Connecting leads heating
elements
In the absence of a fault in the wiring
harness, heating elements,
generator or heating switch, then
the problem may also be due to
damaged connecting leads
between the front and rear handle
heating elements.
– Remove shroud, b 6.4
– Remove handle molding, trigger
interlock and throttle trigger,
b 11.2
– Lower the tank housing and
remove the cover of the plug
connections, b 10.4.1
: Pull connecting lines (1) and (2)
out of the guide (arrows)
: Pull plug connections (1), (2)
and (3) with insulating tubes out
of the guides
2410RA430 TG
1
2
2410RA428 TG
3
1
2
: Push insulating tubes (1) toward
connecting leads and disconnect
plug connections (2) and (3)
Do not disconnect plug
connection (4) with insulating tube.
: Pull plug connections (1) and (2)
with insulating tubes out of the
guides (arrows)
2410RA429 TG
3
1 4
1
2
2410RA431 TG
1
2