Operation Manual

163MS 241 C
System OK
Disconnect and clear plug connections to
front handle heating element,
b 10.4.1
check handle heating
element
resistance approx. 6.4 Ω?
Test heating switch
(contact sleeve against switch housing)
Closed: approx. 0 Ω ?
Open: no continuity,
b 14.3
Reassemble plug connection
to thermostatic switch,
b 13.5
no
no
Replace
front handle,
b 10.4.1
Replace
heating switch,
b 14.4
yes
yes
1
2