Operation Manual
160 MS 241 C
14.7 Generator
– Remove the control unit, b 7.3
– Remove the flywheel, b 7.6
– Remove the pre-separator,
b 7.2
– Remove the carburetor, b 13.5
– Remove carburetor support,
b 13.8
– Remove the air guide shroud,
b 13.4.2
: Remove grommet (1) and
generator lead (2) from the
guide (arrow)
: Remove screws (1)
: Remove generator (2) and pull
the lead (3) out of the
guides (arrows)
: Pull lead (3) out of the opening of
the crankcase
2410RA406 TG
21
2410RA407 TG
2
1
1
3
: Check generator and
poles (arrow) for cracks or other
damage. Replace generator if
necessary.
: Check magnet ring (arrow) in
flywheel for cracks or other
damage. Replace flywheel if
necessary.
0001RA448 TG0001RA449 TG
Installation
– Press the plug connection
together completely, b 1
: Fit generator (1) with connecting
lead (arrow) facing the housing
– Check that the generator is
seated correctly
– Insert and tighten down the
screws
: Push terminal socket (1) of the
generator lead through the
opening (arrow)
2410RA408 TG
1
2410RA409 TG
1