Operation Manual
105MS 241 C
11. Actuating levers
11.1 Master Control lever
The positions of the Master Control
lever are described in the
Instruction Manual.
11.1.1 Removal and installation
– Remove the air filter, b 13.1
– Remove choke rod, b 11.4
– Remove the filter base from the
studs, b 13.1
– Remove contact spring, b 7.7.4
: Turn the switch shaft (1)
counterclockwise as far as it will
go and pull it of off the shaft (2) of
the filter base
– Disconnect ground wire at the
switch shaft, b 7.7
: Take out and examine the switch
shaft (1), replace if necessary
2310RA160 TG
2
1
2310RA161 TG
1
– Examine the filter base, replace if
necessary
Installation
– Position filter base in the
carburetor space
: Position switch shaft (1) in
carburetor space
– Install ground wire on the switch
shaft, b 7.7
: Orient the switch shaft (1) so that
the inserted ground wire faces
the filter base and the
opening (arrow) lines up with the
rib (2)
2310RA162 TG
1
2
2410RA343 TG
1
: Press the switch shaft (1) onto
the post (2) of the filter base as
far as it will go
– Install contact spring, b 7.7.4
: Check correct functioning
– Blade receptacle of the ground
wire must touch the contact
spring (arrow) in position "
0"
– Reassemble remaining parts in
reverse order
2310RA164 TG
2
1
2310RA155 TG