Operation Manual

105MS 241 C
11. Actuating levers
11.1 Master Control lever
The positions of the Master Control
lever are described in the
Instruction Manual.
11.1.1 Removal and installation
Remove the air filter, b 13.1
Remove choke rod, b 11.4
Remove the filter base from the
studs, b 13.1
Remove contact spring, b 7.7.4
: Turn the switch shaft (1)
counterclockwise as far as it will
go and pull it of off the shaft (2) of
the filter base
Disconnect ground wire at the
switch shaft, b 7.7
: Take out and examine the switch
shaft (1), replace if necessary
2310RA160 TG
2
1
2310RA161 TG
1
Examine the filter base, replace if
necessary
Installation
Position filter base in the
carburetor space
: Position switch shaft (1) in
carburetor space
Install ground wire on the switch
shaft, b 7.7
: Orient the switch shaft (1) so that
the inserted ground wire faces
the filter base and the
opening (arrow) lines up with the
rib (2)
2310RA162 TG
1
2
2410RA343 TG
1
: Press the switch shaft (1) onto
the post (2) of the filter base as
far as it will go
Install contact spring, b 7.7.4
: Check correct functioning
– Blade receptacle of the ground
wire must touch the contact
spring (arrow) in position "
0"
Reassemble remaining parts in
reverse order
2310RA164 TG
2
1
2310RA155 TG