Operation Manual
89MS 240, MS 260, MS 260 C
14.4.1 Inlet Needle
– Remove the metering 
diaphragm, b 14.4
: Take out the screw (arrow).
: Pull the inlet control lever (1) with 
spindle (2) out of the inlet 
needle’s groove.
The small spring under the inlet 
control lever may pop out.
: Remove the inlet needle (1).
– Remove the spring (2). Inspect 
and replace if necessary.
165RA345 TG
2
1
165RA345 TG
2
1
165RA347 TG
: If there is an annular indentation 
(arrow) on the sealing cone of the 
inlet needle, fit a new inlet 
needle.
: Fit the inlet needle (1).
: Fit the spring (2) in the bore.
: Position the inlet control lever (3) 
with spindle (2) on the spring’s 
seat (arrow) first, then slide the 
inlet control lever’s clevis into the 
groove in the inlet needle (1).
165RA348 TG
2
1
165RA349 TG
2
1
3
165RA489 TG
Make sure the spring locates on the 
control lever’s nipple.
– Press the inlet control lever down 
and secure it with the screw.
– Check that inlet control lever 
moves freely.
– Install the metering diaphragm, 
b 14.4
14.4.2 Fixed Jet
– Remove the metering 
diaphragm, 
b 14.4
: Unscrew the fixed jet (1) with a 
suitable screwdriver.
Take care not to damage the fixed 
jet (1).
– Check the fixed jet (1) and 
replace if necessary
– Reassemble in the reverse 
sequence.
165RA351 TG