72
Battery is not being charged even though
LED on charger glows green
Battery too hot / too cold
(1 LED on battery glows red)
Allow battery to cool down / at tempera-
tures of about 15°C - 20°C (59°F - 68°F),
allow battery to warm up slowly
Operate charger only in closed, dry
rooms at ambient temperatures of 5°C -
40°C (40°F - 104°F)
LED on charger flashes red
No electrical contact between charger
and battery
Remove the battery and refit it
Malfunction in battery
(4 LEDs on battery flash red for
about 5 seconds)
Take the battery out of the power tool
and refit it. Switch on the machine – if the
LEDs continue to flash, the battery has a
malfunction and must be replaced.
Malfunction in charger Have charger checked by servicing
dealer
1)
1)
STIHL recommends an authorized STIHL servicing dealer.
Always remove the battery before carrying out any work on the power tool.
Condition Cause Remedy