18.1 STIHL HSA 94 R, HSA 94 T
Approved batteries:
–STIHL AR
– STIHL AP together with “AP belt bag with connecting
cable”
Weight without battery
– HSA 94 R, 600 mm: 4.1 kg
– HSA 94 R, 750 mm: 4.4 kg
– HSA 94 T, 500 mm: 3.7 kg
– HSA 94 T, 600 mm: 3.9 kg
– HSA 94 T, 750 mm: 4.1 kg
18.2 Cutting Blades
HSA 94 R
– Tooth spacing: 38 mm
– Cutting length: 600 mm or 750 mm
– Sharpening angle: 45°
HSA 94 T
– Tooth spacing: 30 mm
– Cutting length: 500 mm, 600 mm or 750 mm
– Sharpening angle: 45°
18.3 Noise and Vibration Data
HSA 94 R, 600 mm
– Sound pressure level L
p
measured according to
EN 60745
-
2
-
15: 83 dB(A) K-value for noise pressure level
is 2.5 dB(A).
– Sound power level L
w
measured according to EN 60745-
2-15: 94 dB(A) K-value for noise power level is 2.5 dB(A).
– Vibration measurement a
hv
measured according to
EN 60745-2-15
– Control handle: 3.1 m/s² K-value for vibration level is
2.0 m/s².
– Loop handle: 3.6 m/s² K-value for vibration level is 2.0
m/s².
HSA 94 R, 750 mm
– Sound pressure level L
p
measured according to
EN 60745
-
2
-
15: 84 dB(A) K-value for noise pressure level
is 2.5 dB(A).
– Sound power level L
w
measured according to EN 60745-
2-15: 95 dB(A) K-value for noise power level is 2.5 dB(A).
– Vibration measurement a
hv
measured according to
EN 60745-2-15
– Control handle: 3.3 m/s² K-value for vibration level is
2.0 m/s².
– Loop handle: 4.2 m/s² K-value for vibration level is 2.0
m/s².
HSA 94 T, 500 mm
– Sound pressure level L
p
measured according to
EN 60745
-
2
-
15: 84 dB(A) K-value for noise pressure level
is 2.5 dB(A).
– Sound power level L
w
measured according to EN 60745-
2-15: 95 dB(A) K-value for noise power level is 2.5 dB(A).
– Vibration measurement a
hv
measured according to
EN 60745-2-15
– Control handle: 2.7 m/s² K-value for vibration level is
2.0 m/s².
18 Specifications