Operators Manual
Table Of Contents
- Contents
- 1. Introduction and safety precautions
- 2. Specifications
- 3. Troubleshooting
- 4. Clutch
- 5. Engine
- 6. Ignition system
- 6.1 Ignition timing
- 6.2 Ignition module
- 6.3 Testing the ignition module
- 6.4 Spark plug boot / ignition lead
- 6.5 Flywheel
- 6.6 Short circuit wire
- 6.6.1 Testing
- 6.6.2 Short circuit wire on engine, removal and installation
- 6.6.3 Short circuit wire with M-Tronic on engine, removal and installation
- 6.6.4 Short circuit wire on control handle for loop handle, removal and installation
- 6.6.5 Short circuit wire on control handle for bike handle, removal and installation
- 6.6.6 Ground wire
- 6.6.7 Contact spring versions with control handle for bike handle
- 6.7 Troubleshooting, Ignition System
- 7. M-Tronic
- 8. Rewind starter
- 9. Antivibration elements
- 10. Actuating levers
- 11. Fuel system
- 12. Drive tube assembly
- 13. Special tools
- 14. Service accessories
61FS 240 C, FS 260 C, FS 360 C, FS 410 C, FS 460 C-M
Check leads between control unit
and diagnostic jack
– Connect the test lead, b 7.3.2
: Measure the resistance between
red lead (1) and black plug (2) of
the diagnostic cable
Target value: < 10 ohms.
: Measure the resistance between
black lead (1) and red plug (2) of
the diagnostic cable
Target value: < 10 ohms.
If the target values are not
attained
– Check that screw on control unit
(ignition module) and screw on
angled terminal socket are firmly
seated, if necessary, remove
screws and clean with angled
terminal socket, then reinsert and
tighten
5904RA286 TG
1 2
5904RA547 TG
1 2
– Check continuity between blade
receptacle and angled terminal
socket
– Blade receptacle and angled
terminal socket must be firmly
connected with one another; in
the event of contact problems,
the M-Tronic wiring harness must
be replaced, b 7.4.
Check leads between solenoid
valve and diagnostic jack
– Connect the test lead, b 7.3.2
: Disconnect the plug (1) from the
solenoid valve (2)
: Measure the resistance between
red lead (1) at the plug of the
solenoid and black plug (2) of the
diagnostic cable
Target value: < 10 ohms
2
5904RA282 TG
1
5904RA288 TG
1
2
: Measure the resistance between
black lead (1) at the plug of the
solenoid and red plug (2) of the
diagnostic cable
Target value: < 10 ohms
If the target values are not
attained
– Check contact surfaces between
lug and screw and check leads
for interruptions, e. g., cable
breakage – the leads must be
firmly seated in the blade
receptacle and in the lug.
5904RA289 TG
1
2