Operators Manual
Table Of Contents
- Contents
- 1. Introduction and safety precautions
- 2. Specifications
- 3. Troubleshooting
- 4. Clutch
- 5. Engine
- 6. Ignition system
- 6.1 Ignition timing
- 6.2 Ignition module
- 6.3 Testing the ignition module
- 6.4 Spark plug boot / ignition lead
- 6.5 Flywheel
- 6.6 Short circuit wire
- 6.6.1 Testing
- 6.6.2 Short circuit wire on engine, removal and installation
- 6.6.3 Short circuit wire with M-Tronic on engine, removal and installation
- 6.6.4 Short circuit wire on control handle for loop handle, removal and installation
- 6.6.5 Short circuit wire on control handle for bike handle, removal and installation
- 6.6.6 Ground wire
- 6.6.7 Contact spring versions with control handle for bike handle
- 6.7 Troubleshooting, Ignition System
- 7. M-Tronic
- 8. Rewind starter
- 9. Antivibration elements
- 10. Actuating levers
- 11. Fuel system
- 12. Drive tube assembly
- 13. Special tools
- 14. Service accessories
60 FS 240 C, FS 260 C, FS 360 C, FS 410 C, FS 460 C-M
7.3.5 Checking the start
detection function
– Carry out test preparations,
b 7.3.1
– Check contacts and operation,
b 7.3.3
– Connect the test lead, b 7.3.2
: Disconnect the plug (1) from the
solenoid valve (2)
: Remove screws (1)
: Pull out the blue lead (2) and red
lead (3)
– Move choke lever to
position "}" – slide control or
lever for stop function on control
handle is not pressed
2
5904RA282 TG
1
1
5904RA283 TG
1
3
2
– Connect M-Tronic test lead to
multimeter
: Insert black plug (1) in the "com"
/ "ground" jack and the red
plug (2) in the "volt" / "ohm" jack
– Set multimeter to "diode test"
: Test diode on switchgear (3)
(microswitch) in accordance with
multimeter instruction manual
If the switchgear (microswitch) is
intact and the choke lever is set to
the "}" position, the following
target values will be attained:
– Measurement in direction of flow,
target value: 0.3 volts to 0.7 volts
– Move choke lever to position "F"
– slide control or lever for stop
function on control handle is not
pressed
– Reverse-biased measurement
Target value: 1.2 volts to infinity
– If target values are not attained,
replace M-Tronic wiring harness,
b 7.4
1
5904RA284 TG
2
3
7.3.6 Checking the wiring
harness
– Carry out test preparations,
b 7.3.1
– Check contacts and operation,
b 7.3.3
– Move choke lever to position "F"
Checking the ground connection
: Measure the resistance between
blade receptacle (1) and
screw (2) at the control unit
(ignition module)
Target value: < 10 ohms.
If the target values are not
attained
– Check electrical leads for
interruption, e. g., cable
breakage – if necessary, replace
M-Tronic wiring harness, b 7.4.
5904RA287 TG
1
2