Operators Manual
Table Of Contents
- Contents
- 1. Introduction and safety precautions
- 2. Specifications
- 3. Troubleshooting
- 4. Clutch
- 5. Engine
- 6. Ignition system
- 6.1 Ignition timing
- 6.2 Ignition module
- 6.3 Testing the ignition module
- 6.4 Spark plug boot / ignition lead
- 6.5 Flywheel
- 6.6 Short circuit wire
- 6.6.1 Testing
- 6.6.2 Short circuit wire on engine, removal and installation
- 6.6.3 Short circuit wire with M-Tronic on engine, removal and installation
- 6.6.4 Short circuit wire on control handle for loop handle, removal and installation
- 6.6.5 Short circuit wire on control handle for bike handle, removal and installation
- 6.6.6 Ground wire
- 6.6.7 Contact spring versions with control handle for bike handle
- 6.7 Troubleshooting, Ignition System
- 7. M-Tronic
- 8. Rewind starter
- 9. Antivibration elements
- 10. Actuating levers
- 11. Fuel system
- 12. Drive tube assembly
- 13. Special tools
- 14. Service accessories
11FS 240 C, FS 260 C, FS 360 C, FS 410 C, FS 460 C-M
3.4 Starter
Problem Cause Remedy
Starter rope broken Rope pulled out too vigorously as
far as stop or over edge, i.e. not
vertically
Replace starter rope
Normal wear Replace starter rope
Starter rope does not rewind Heavy fouling or rust on rewind
spring
Clean or replace rewind spring
Spring insufficiently tensioned Check rewind spring and increase
tension
Rewind spring broken Replace rewind spring
Starter rope cannot be pulled out
far enough
Rewind spring overtensioned Check rewind spring and reduce
tension
Starter rope can be pulled out
almost without resistance
(crankshaft does not turn)
Guide peg on pawls or pawls
themselves are worn
Replace pawls
Spring clip fatigued Replace spring clip
Spring clip improperly installed Install spring clip properly
Lugs on starter cup worn Replace starter cup, check pawls,
replace if necessary
Anchor loop in ErgoStart spring
housing not hooked onto carrier
Hook ErgoStart anchor loop to
carrier