Operation Manual
TheYROWDJHRI\RXUSRZHUVXSSO\and
the YROWDJHVSHFLILHGRQWKHVDZmust
be the same.
2XWGRRURSHUDWLRQ: Connect the saw
via a ground-fault circuit breaker.
Extension cord must be suitable for
outdoor use.
0DLQVSRZHURXWOHW: Must be equipped
with a fuse or automatic circuit breaker.
If the fuse or circuit breaker is tripped
when you switch on the saw, use an
extension cord (at least 10m/35 ft long)
that meets the specifications in the
following table.
([WHQVLRQFRUGV:
Minimum wire size for extension cords
for 120 Volt appliances:
cord types: SJW-A or SJTW-A
Round jacketed cords.
cord length (feet) 50 100 150
wire size (AWG) 14 12 10
Using not more than 15 amps:
cord length (feet) 50 100 150
wire size (AWG) 10 * *
* not recommended
Listed by UL, W-A marking on cable jak-
ket indicates "use outdoor".Appro-priate
extension cords are available in special
stores for electrical equipment.
&DEOHGUXP: Always unwind the cord
completely. It should be equipped with
thermal protection.
•
Make sure you have a firm footing.
•
Check that bystanders are well
clear of general work area of the
saw.
•
Hold the saw firmly with both hands.
•
Disengage the chain brake by
pulling hand guard back toward the
front handle.
•
Check that the chain is not touching
any object or the ground.
•
Press in the trigger switch interlock
with your thumb.
•
Squeeze the trigger switch with
your index finger.
•
Start cutting with the chain running.
•
Release the trigger switch so that it
can return to the off position . It is
then locked in this position by the
trigger switch interlock.
&RQQHFWLQJ6DZWR
3RZHU6XSSO\
6ZLWFKLQJ2Q
2
1
107BA009 KN
6ZLWFKLQJ2II
26 E 220