17 Troubleshooting
17.1 Troubleshooting Blower or Battery
17 Troubleshooting
Condition LEDs on Battery Cause Remedy
Blower does not start
when switched on
1LED flashes
green.
Battery has low charge. Recharge the battery fully as described in the
instruction manual for the STIHL AL 101, 300, 500
chargers.
1 LED glows red. Battery too hot or too cold. Remove the battery.
Allow battery to cool down or warm up.
3 LEDs flash red. There is a malfunction in
the blower.
Remove the battery.
Clean contacts in battery compartment.
Fit the battery.
Switch on the blower.
If 3 LEDs continue to flash red: Do not use the
blower and contact your STIHL servicing dealer for
assistance.
3 LEDs glow red. Blower is too hot. Remove the battery.
Allow blower to cool down.
4 LEDs flash red There is a malfunction in
the battery.
Remove battery and insert it again.
Switch on the blower.
If 4 LEDs continue to flash red: Do not use the
battery and contact your STIHL dealer for
assistance.
No electrical contact
between blower and
battery.
Remove the battery.
Clean contacts in battery compartment.
Fit the battery.
Blower or battery damp. Allow blower or battery to dry.
Blower cuts out
during operation
3 LEDs glow red. Blower is too hot. Remove the battery.
Allow blower to cool down.
There is a electrical
malfunction.
Remove battery and insert it again.
Switch on the blower.
Blower runtime is too
short
Battery not fully charged. Recharge the battery fully as described in the
instruction manual for the STIHL AL 101, 300, 500
chargers.
Normal battery life has
been exceeded.
Replace the battery.