Owner's Manual
ADG 2
English
7
If there is a fault in the cordless power
tool ...
Depending on the fault, the light emitting
diode on the analyzer glows
continuously yellow or red:
– Red continuous light: Active fault,
cordless power tool not ready for
operation – a damage code is
displayed.
– Yellow continuous light: Intermittent
fault in the past (e.g. loose contact),
cordless power tool ready for
operation – the fault can be called
up in the power tool's fault memory.
The two-digit code on the display
(shown as XX in the description)
indicates the cause of the fault in the
cordless power tool. In case of claims,
always quote the code on the warranty
request form.
Always remove the adapter from the
power tool before starting repair.
N Press in both locking tabs (1) at the
same time to unlock the adapter (2).
N Take the adapter (2) out of the
housing.
N Press the lower button to confirm.
The data of the cordless power tool
remains stored in the analyzer for about
30 minutes.
When the adapter is removed, any
active faults and entries in the fault
memory are shown. Scroll between the
displays with the analyzer's
pushbuttons. For repair procedure, see
Technical Information bulletins on
ADG 2 analyzer and the cordless power
tool concerned.
Clearing the fault memory
The fault memory may be cleared after
completing the repair.
N After viewing last entry in fault
memory, press the lower button.
N Press and hold down both buttons
for about 3 seconds.
N Press the lower button to confirm
that the fault memory should be
cleared.
N Insert the adapter in the cordless
power tool.
N Switch on the cordless power tool –
see power tool's instruction manual.
Fault memory is cleared. To avoid
damage to the electronic module, the
adapter must not be removed from the
cordless power tool and the battery must
not be removed from the analyzer while
the memory is being cleared.
On completion, the analyzer's display
confirms that the memory has been
cleared.
The test is restarted by pressing the
lower button.
After the test
N Remove the battery from the
analyzer.
When the battery is removed, the data of
the cordless power tool that has been
tested is deleted from the analyzer. The
analyzer can then be used to test further
cordless power tools.
Damage code
XX
Remove adapter before
repair
Clear memory?
Press both buttons
Clear: no
Clear: yes
2
1
7BA004 KN
1
Insert adapter,
switch on unit
Do not remove unit
Memory cleared
End of test