Owner's Manual

ADG 2
English
6
The cordless power tool's motor starts to
run during the test. Before starting the
test, always take precautions to avoid
the risk of injury from contact with the
attachment or operation of the power
tool.
The following instructions appear on the
display:
N Eliminate risk from tool – see
Technical Information bulletins on
ADG 2 analyzer and the cordless
power tool being tested.
N Press the lower button to confirm.
N Insert adapter (1) in power tool's
battery compartment – the adapter
slides into position – press it in until
it engages audibly. The adapter
must be flush with the top of the
housing.
N Press the lower button to confirm.
N Press the lower button to confirm.
Data transfer
The cordless power tool and analyzer
communicate with each other. The
analyzer can test the cordless power
tool only if this data exchange functions.
N Switch on the cordless power tool
for about 3 seconds – see power
tool's instruction manual.
If there is no data exchange between the
power tool and the analyzer, the
problem is in the connection to the
power tool – refer to Technical
Information bulletins on ADG 2 analyzer
and the power tool concerned.
N Switch on cordless power tool again
for about 3 seconds – the test is
started.
Checking operation of controls
The controls differ according to the
cordless power tool being tested. The
following procedure describes the
trigger switch on the FSA 85 cordless
trimmer as an example.
The display always shows the current
position of the control:
N Operate trigger switch
Release trigger switch after a few
seconds. If the trigger switch is
depressed for longer the test results
may be falsified or the analyzer may
shut down automatically.
If the switch is in order, the display
changes when the trigger is operated
and the light emitting diode on the
analyzer glows green:
If the display does not change or a value
of 100% is not reached with the control
fully depressed, there is a fault in the
control – refer to troubleshooting
procedure in Technical Information
bulletins on ADG 2 analyzer and the
power tool concerned.
N For further fault display, press the
lower button.
Fault display
If there are no faults in the cordless
power tool ...
The light emitting diode on the analyzer
glows continuously green.
The test is restarted by pressing the
lower button.
Eliminate risk from tool
Insert adapter
CAUTION: Motor may start
1
7BA003 KN
Switch on unit
Data transfer
Switch unit on again
Operate trigger switch
OFF 0%
Operate trigger switch
ON 100%
No fault
End of test