Operation Manual
•
Remove four screws -
•
push the hand guard upward -
•
pull underside of fan housing away
from crankcase
and remove it downward
•
Use a screwdriver to pry the rope
out of the starter grip.
•
Remove remaining rope from the 
rotor and starter grip.
138BA017 L
Ä
5HSODFLQJ6WDUWHU5RSHDQG
5HZLQG6SULQJ
001BA002 KN
1
2
3
3
000BA036 TR
1
•
Fit a new spark plug after 
approx. 100 operating hours -
or earlier if the electrodes are
badly eroded.
:DUQLQJ
To reduce the risk of fire and burn injury,
use only spark plugs authorized by
STIHL (see “Specifications”). Always
press spark plug boot  snugly onto
spark plug terminal  of the proper
size. (Note: If terminal has detachable
SAE adapter nut, it must be attached.) 
A loose connection between spark plug
terminal and ignition wire connector in
the boot may create arcing that could 
ignite combustible fumes and cause a
fire.
 