Operation Manual
51
User’s manual
EN
Problem
Cause
Remedies
Secondary area not
completely mowed
Incorrect
programming
Correctly program the secondary area
(see “Programming Mode”)
On the display appears
“No Signal”
The perimeter wire
is not connected
correctly (broken
cable, no electrical
connection, etc.)
Check the functioning of the electrical power
supply, the correct connection of the power
supply-transmitter unit and that of the charging
station (see “Installation of charging station and
power supply-transmitter unit”)
On the display appears
“Out of border”
Too much slope
Delimit the area with too much slope (see
“Planning of plant installation”).
Perimeter wire laid
incorrectly
Check that the wire has been installed
correctly (e.g. too deep, next to metallic
objects, distance between the wire marking
the two elements less than 70 cm, etc.) (see
“Planning of Plant Installation”)
Perimeter wire mar-
king the boundary
of the inside areas
( owerbeds, bushes,
etc.) laid in an anti-
clockwise direction.
Reposition the perimeter wire correctly
(anti-clockwise direction) (see “Installation of
perimeter wire”)
Overheated power
supply unit
Adopt the appropriate measures to reduce
the temperature of the power supply unit
(ventilate or modify the installation area, etc.)
(see “Planning of plant installation”)
Incorrect wheel
transmission
Check and, if necessary,
correctly fasten the wheels