Instruction Manual

1
For all types of installations:
Mount the end cap. +
16
17
20
19
18
Screw on the connections,
pull tight with a spanner and
push the insulation over the
corrugated hose.
16 17
i
Caution! The euro-conus connector or the sensor T-piece should always be mounted ont he
collector discharge side. For laterally-inverted connections, the adapter (Art.-No. 791069) should
be used. + +
18 19
20
21
22
23
On the left hand side: lubricate the o-ring of the collector connection with silicone grease, connect the
corrugated hose, push the side cap over the corrugated hose and mount. Following this pull the insula-
tion over the hose. + +
21
22
23
14
Installation instructions
SP-20 SP-30