The appliance must be connected to the power supply taking the
applicable installation instructions and the relevant standards and re-
gulations into consideration. It is particularly important to observe the
“Regulations for installing high-voltage systems with rated voltages up
to 1000 V” and regulations from the local power supply company. The
appliances are only designed for permanent connection to a 230 V ~
AC network. For this, install an isolator that disconnects all poles of the
power cable with at least 3 mm contact separation (e.g. fuse).
!
Electrical connection should be carried out by an authorised
fitter only.
When delivered, the PSH 30 ... 200 wall-mounted storage heaters are
wired in the way shown in circuit diagram 2.
Initial Start-up
The specialist technician must monitor the appliance when it is put into
operation and heats water for the first time.
Maintenance
The outside of the storage heater does not require any special mainte-
nance. To clean, wipe using a soft cloth or damp sponge only. Do not
use any abrasive agents or aggressive detergents.
!
Caution! Always fully disconnect the appliance from the power
supply before carrying out any maintenance work.
Technical specifications
Type PSH 30 TM 50 TM 80 TM 100 TM 120 TM 150 TM 200 TM
Rated voltage 1/N/PE ~ 230V
power consumption W 2000 2000 2000 2000 2000 2000 2000
Nominal capacity Liter 30 50 80 100 120 150 200
Power consumption in stand-by
mode
kWh/d
0,73
0,93
1,16
1,48
1,71
2,01
2,90
Drawable quantity of mixed
water
at 40 °C
(1)
Liter
56,2
101,5
144,3
186
227,9
291
385,3
Weight (empty) kg 16 21 26 30 34 41 50
Weight (wet) kg 46 71 106 130 154 191 250
Dimensions A mm 100 100 100 100 100 100 100
B mm 296 296 274 274 274 274 274
C mm 47 47 28 28 28 28 28
D mm 390 390 470 470 470 470 470
E mm 530 591 583 735 889 1125 1425
H mm 585 840 810 962 1116 1352 1652
I mm 102 296 255 255 255 255 255
K mm 386 386 485 485 485 485 485
M mm 78 78 75 75 75 75 75
X mm G 1/2“ G 1/2“ G 3/4“ G 3/4“ G 3/4“ G 3/4“ G 3/4“
Permissible operating pressure MPa 0,6
Degree of protection Protection against water jets (IP 25)
Mark of conformity See rating plate
(1)
Cold water inlet 15 °C and cylinder temperature 65 °C
To ensure a long service life, it is recommended to have a specialist
technician inspect the anti-corrosion anode (magnesium anode) in the
appliance once per year. This check may need to be carried out more
frequently in areas with particularly aggressive water – ask the fitter or
your local water supply company for information.
The appliance is protected against overheating by a safety temperature
limiter which interrupts all phases. If the safety temperature limiter has
been triggered, an authorised specialist technician is required to carry
out the repair work. The high limit safety cut-out can be reset by pres-
sing the pushbutton (marked Safety) on the controller below the control
panel cover.
Dimensions 4
Dimensions of storage heater (see table “Technical specifications”)
1 Heating flange
2 Magnesium anode
3 Delivery pipe
4 Temperature selection knob
5 Mounting bracket
6 Signal lamp
Installation type 3
1 Safety valve
2 Non-return valve
3 Pressure test connection
4 Stop valve
5 Pressure reducer
6 Drawing points
7 Drain outlet / siphon