Installation Sheet
ENGLISH
WWW.STIEBEL-ELTRON-USA.COM MINI
™
-E SERIES TANKLESS ELECTRIC WATER HEATERS | 9
INSTALLATION
Note:
Fitting the supplied aerator provides an optimum water
fl ow.
10. Installation
10.1 Installation site
Do not install in an area that can be exposed to temperatures below
41°F / 5°C.
Ensure access to the opening screws on both sides of the cover so
that they can be easily removed if service is necessary.
The appliance is suitable for an undersink or oversink installation. It
can be installed with water connections at the top or at the bottom.
DANGER: Electrocution
The adjusting screw for setting the temperature is 'live',
and the IP25 protection is only given when the appliance
back panel is fi tted.
10.2 Installation options
10.2.1 Typical installation
26_02_05_0093
1
2
1 Tee
2 Shut-off valve