User Manual
ENGLISH
www.stiebel-eltron.com HDB-E Si | 21
INSTALLATION
Installation
f Drill the holes and secure the mounting bracket with
2screws and 2rawl plugs (screws and rawl plugs are not
part of the standard delivery).
Note
If you are installing the appliance with flexible water con-
nections, secure the back panel with a screw.
f Fit the mounting bracket.
160
30
26_02_02_0887
f Prepare the power cable.
Making the water connection
!
Material damage
Carry out all water connection and installation work in
accordance with regulations.
68 ±2
53 ±2
19
G 3/8 A
19
G 1/2 A
26_02_02_1368
f Seal and insert the twin nipples.
Fitting the strainer
!
Material damage
The strainer must be fitted for the appliance to function.
f When replacing the appliance, check that the strain-
er is present.
26_02_02_1364
f Fit the strainer provided in the cold water inlet of the
appliance.
Installing the DMB flow limiter
26_02_02_1365
f Install the flow limiter provided in the cold water inlet of the
appliance.
Installing the appliance
26_02_02_1372
f For easy installation, push the cable grommet of the upper
electrical connection into the back panel from behind.
f Remove the transport plugs from the water connections.
f Remove the fixing toggle from the upper part of the back
panel.
f Route the power cable from behind through the cable grom-
met until it rests against the cable sheath. Align the power
cable.
In the case of a cross-section >6mm², enlarge the hole in
the cable grommet.
f Push the appliance over the threaded stud of the mounting
bracket, so that it breaks through the soft seal. If necessary,
use a screwdriver.