7.12 Technical data
(the data on the unit rating plate are applicable)
Hydraulically controlled instantaneous water heaters
Type
DHF 13 C
compact
control
DHF 13 C-A
compact
control
DHF 15 C
compact
control
DHF 18 C
compact
control
DHF 21 C
compact
control
DHF 24 C
compact
control
DHF 12 C1
compact
control
DHF 13 C3
compact
control
Part no. 074301 222214 074302 074303 074304 074305 182137 185708
Rated voltage
Partial power
Rated power
Stage
Stage
••
V
kW
kW
400
6.6
13.2
400
6.6
13.2
400
7.5
15
400
9
18
400
10.5
21
400
12
24
220
8
12
230
8.8
13.2
230
6.6
13.2
Min. flow rate to activate Stage
Stage
••
l/min
l/min
2.5
3.7
3.0
4.5
3.0
4.5
3.9
5.9
4.4
6.4
4.9
7.6
2.5
3.7
2.5
3.7
2.5
3.7
Flow rate limiter l/min 4.5 6.5 6.5 7.0 7.5 8.0 4.5 4.5 4.5
Pressure loss*
Flow rate
MPa
l/min
0.05
3.7
0.055
4.5
0.055
4.5
0.06
5.9
0.06
6.4
0.07
7.6
0.05
3.7
0.05
3.7
0.05
3.7
Nominal water volume l 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6
Type of construction closed x x x x x x x x x
Rated overpressure MPa 1 1 1 1 1 1 1 1 1
Weight kg 4.0 4.0 4.0 4.0 4.0 4.0 4.0 4.0 4.0
Protection class to EN60335 1 1 1 1 1 1 1 1 1
Protection mode to EN60529 IP 24 IP 24 IP 24 IP 24 IP 24 IP 24 IP 24 IP 24 IP 24
Test mark, see unit rating plate x x x x x x x x x
Water connection external thread G ½ G ½ G ½ G ½ G ½ G ½ G ½ G ½ G ½
Electrical connection
3/PE ~ 400 V x x x x x x
1/N/PE ~ 220 V x
1/N/PE ~ 230 V x
3/PE ~ 230 V x
Max. mains impedance Z max to
EN61000-3-11
Ω
-
-
-
-
-
0.44
0.15
0.14
0.45
Heating element Copper tubular
heating elementr
x
x
x
x
x
x
x
x
x
Cold water inlet °C ≤ 20 ≤ 30 ≤ 20 ≤ 20 ≤ 20 ≤ 20 ≤ 20 ≤ 20 ≤ 20
Use in waters
Total alkaline earths mol/m³ ≤ 2.5 ≤ 2.5 ≤ 2.5 ≤ 2.5 ≤ 2.5 ≤ 2.5 ≤ 2.5 ≤ 2.5 ≤ 2.5
Overall hardness (earlier unit) °d ≤ 14 ≤ 14 ≤ 14 ≤ 14 ≤ 14 ≤ 14 ≤ 14 ≤ 14 14
Hardness range (earlier unit) Inclusive of 2 (me-
dium hard)
x
x
x
x
x
x
x
x
x
Table 3
* Pressure drop values also apply to the minimum flow pressure in accordance with DIN44851 / Flow rate for heating from 10 °C to 55 °C
(∆-ϑ 45 K). A pressure drop of 0.1MPa (1 bar) is recommended for pipe network dimensioning, in line with DIN 1988 Part 3, Table 4.
7.13 Fault finding - qualified installer
Cause Cause » Remedy
Unit does not switch on. Water pressure in cold water pipe too low. Descale or replace showerhead/Perlator®.
Strainer in 3-way valve (6) fouled. Clean strainer (
D
, 22).
Differential pressure switch (10, control valve MRC)
with flow rate controller does not switch on in spite
of the hot water tap being turned fully on.
Necessary switch-on quantity to switch on the hea-
ting output is not reached.
Clean strainer (
D
, 22).
Check water pressure.
Unit does not produce hot water in spite of an audible
switch-on noise by the differential pressure switch.
Safety temperature limiter (12) has tripped, possibly
due to:
Intlet temperature too high. Check intlet temperature.
Control valve (MRC) faulty.
Check and if necessary replace control valve. Rinse
heating-system of unit, in order to avoid over-hea-
ting. Press reset button (13).
Element scaled up. De-scale or replace element.
Heating system does not heat water. No voltage. Check fuse (house installation).
Heating system faulty. Replace tubular heating element heating system (11).
Table 4