Operating Instructions and Installation Instructions

ENGLISH
www.stiebel-eltron.com DHE SLi | 35
INSTALLATION
Commissioning
11. Commissioning
WARNING Electrocution
Commissioning may only be carried out by an authorised
contractor in accordance with safety regulations.
11.1 Commissioning
Open the cross-piece.
on
on
26�02�02�0554
Open and close all connected draw-off valves several times,
until all air has been vented from the pipework and the
appliance.
Carry out a tightness check.
Activate the safety switch (AE 3) by firmly pressing in the
reset button (the appliance is delivered with the safety switch
deactivated).
Push the set value transducer cable plug onto the PCB.
Fit the appliance cap and secure it with a screw.
Switch the mains power ON.
Check the function of the appliance.
Remove the protective foil from the user interface.
Appliance handover
Explain the appliance function to users and familiarise them
with its operation.
Make the user aware of potential dangers, especially the risk
of scalding.
Hand over these instructions.
11.2 Recommissioning
!
Material damage
Following an interruption of the water supply the appli-
ance must be recommissioned by carrying out the follow-
ing steps, in order to prevent the destruction of the bare
wire heating system.
Disconnect the appliance from the power supply by
removing the fuses/tripping the MCBs.
Open the tap for one minute until the appliance and
its upstream cold water inlet line are free of air.
Switch the mains power back ON again.
12. Service mode
D0000046159
Open the appliance cover and hook it on the side of the back
panel.
26�02�02�0556�
1
1 Service button for activating and deactivating service mode
Key to symbols
Press once START
Press once END
Change settings/ scanning
In service mode you are able to call up and/or change the set
temperature using the M key (60°C).