Operating Instructions and Installation Instructions
32 | DHB-E SLi www.stiebel-eltron.com
INSTALLATION
Installation options
13.8 Fitting the base part of the back panel with
threaded fittings on finished walls
If using threaded connections for finished walls, the base part of
the back panel can also be installed after fitting the taps. To do
this, carry out the following steps:
Saw open the base part of the back panel.
Fit the base part of the back panel by bending it out at the
sides and guiding it over the pipes.
Insert the connection pieces into the base part of the back
panel from behind.
Click the base part into place in the back panel.
Secure the base part of the back panel with a screw.
2
1
26�02�02�1080
3
1 Base part of the back panel
2 Connection pieces delivered in the pack
3 Screw
13.9 Wall mounting bracket when replacing an
appliance
An existing STIEBELELTRON wall mounting bracket may be used
when replacing appliances (except for DHF instantaneous water
heater).
Break through the back panel of the appliance for the thread-
ed stud on the installed wall mounting bracket.
Replacing a DHF instantaneous water heater
26�02�02�0815�
Reposition the threaded stud on the wall mounting bracket
(the stud has a self-tapping thread).
Rotate the wall mounting bracket 180° and mount it on the
wall (the DHF logo is then turned towards the reader).
13.10 Installation with offset tiles
110
20
26�02�02�1066�
2
1
1 Minimum contact area of the appliance
2 Maximum tile offset
Adjust the wall clearance. Lock the back panel in place using
the fixing toggle (turn 90° clockwise).
13.11 Pivoting appliance cover
The appliance cover can be turned round for undersink instal-
lation.
26�02�02�0817
Remove the programming unit from the appliance cover by
pressing the locking hooks.
Turn the appliance cover and click the programming unit
back into place, ensuring that all locking hooks are engaged.
For easier installation of the programming unit, press against
the inner side of the appliance cover in the shaded area.
!
Material losses
Do not install a programming unit with faulty locking
hooks. Otherwise the safety of the appliance cannot be
guaranteed.
Plug the set value transducer cable into the PCB (see chapter
"Installation/ Commissioning/ Initial start-up").
Hook the appliance cover in at the top. Pivot the appliance
cover down onto the back panel and press down until it en-
gages audibly.