Owner's manual

INSTALLATION
COMMISSIONINO
9.5.11 Installation for offsettiles
This appliance can be instal led where tiles are offset. See diagram
for maximum tile offset and minimum contact area of the appliance.
Adjust the wnl I clearance and lock the back panel with the fixing
toggle by turning it clockwise through 90*^.
10. Commissioning
A
Danger of electrocution
Commissioning must only be carried out by an author
ised contractor in accordance with safety regulations.
»Open and close allconnected draw-offvalves several times, until
all air has been vented from the pipework and the appliance.
» Activatethe safety pressure limiter by pressing the reset button.
The appliance is supplied with the safety pressure limiter
deactivated.
»Push the temperature selector plug into the "settemperature"
PCB. Ensure thatthe gasket pocket on the lower part of the back
panel is not bent and that it seals the lower part of the user
interface while the appliance cap is being installed.
»Fit the appliance cap nnd secure with a screw.
» Switch the mains power ON.
»Calibrate the temperature by turning the temperature selector
as far as possible clockwise nnd then anti-clockwise.
y> Check the appliance function.
» Remove the protective foil from the user interface.
11. Appliance handover
y> Explain the appliance function to the user and familiarise him/
her with its operation.
»Make the user aware of potential dangers, especially the risk
of scalding.
» Hand over these instructions to the user for safe-keeping.
32 I DHB-E ... SiL electronic vrww.stiebeL-eltron.com