5. Cleaning, care and maintenance
Never use abrasive or corrosive cleaning agents. A damp
cloth is sufficient for cleaning the appliance.
Check the taps regularly. Limescale deposits at the tap out-
lets can be removed using commercially available descaling
agents.
6. Troubleshooting
Problem Cause Remedy
The appliance will not
start despite the DHW
valve being fully open.
There is no power.
Check the fuses/MCBs in
your fuse box/distribu-
tion panel.
The aerator in the tap
or the shower head is
scaled up or contami-
nated.
Clean and/or descale the
aerator or shower head.
When hot water is being
drawn off, cold water
flows for a short period.
The air sensor detects air
in the water and briefly
switches the heater off.
The appliance restarts
automatically after
1minute.
Required temperature
>45°C is not achieved.
The water supply has
been interrupted.
Vent the appliance and
the cold water supply line
(see chapter "Operation/
Recommended settings/
Following an interruption
to the water supply").
Cold water inlet tempera-
ture is >45°C.
Reduce the cold water
inlet temperature.
If you cannot remedy the fault, notify your qualified contractor.
To facilitate and speed up your request, provide the number from
the type plate (000000-0000-000000).