Operating Instructions and Installation Instructions
ENGLISH
10.3.11 Installation for offset tiles
This appliance can be installed where tiles are offset. See
diagram for maximum tile offset and minimum contact area of
the appliance. Adjust the wall clearance and lock the back panel
with the fixing toggle by turning it clockwise through 90°.
110
20
26�02�02�0829
11. Commissioning
WARNING Risk of electrocution
Commissioning must only be carried out by an authorised
contractor in accordance with safety regulations.
30
60
45
35
40
50
55
°C
el ec tro ni c
30
60
45
35
40
50
55
°C
el ec tro ni c
..
2..
26�02�02�1183
Open and close all connected draw-off valves several times,
until all air has been vented from the pipework and the
appliance.
Activate the safety pressure switch at flow pressure by
pressing the reset button. The appliance is supplied with the
safety pressure limiter deactivated.
Push the temperature selector plug into the "set
temperature" PCB.
Fit the appliance cap and secure with a screw.
Switch the mains power ON.
Calibrate the temperature by turning the temperature
selector as far as possible clockwise and then anti-clockwise.
Check the appliance function.
Remove the protective foil from the user interface.
12. Appliance handover
Explain the appliance function to the user and familiarise
him/her with its operation.
Make the user aware of potential dangers, especially the risk
of scalding.
Hand over these instructions to the user for safe-keeping.