2. Remove end plate from heater: 6 Phillips screws fasten the
heater body end plate in place:
3. Remove 4 Phillips screws that hold connection box to heater:
4. Remove the 2 Phillips screws that fasten the electrical
connection box front face plate in place:
5. Slide the connection box front face plate out from the electrical
connection box:
6. Slide power cord retainer plate from electrical connection box
(top surface):
7. Loosen screws in terminal block to remove wires as required:
» RED wires connect to Lamp #1 (closer to connection box)
» BLUE wires connect to Lamp #2 (further end from box)
» Do not disconnect power supply wires
» Loosen the threaded clamping collar on the Liquid Tight
Connector located behind the wiring terminal
» Pull wires out through the Liquid Tight Connector and top of
electrical connection box:
Electrical